Air-Oxygen-Blender (O2-Blender) are used to administer a continuous, precise mix of medical air and medical oxygen through its outlet ports to infants, children and adults. The exact fractional inspired oxygen concentration (FIO2) corresponds to the selected FIO2 setting on the control knob, which can be adjusted from 21% to 100%
Quality Mix Low Flow Air-Oxygen-Blender
• Total flow maximum: 45 LPM
• With switchable bleed-function (on/off)
• Configurable with up to 3 flowmeters
• An oxygen monitor can be added to the Blender to
check the precise FiO2 concentration
• With an extra pressure module, different input
pressures of AIR and O2 can be compensated
• Audible warning in case of gas failure
• Robust and intelligent design due to recessed
adjusting knob
• The O2 mixer is MRI compatible
Order Number: QM-LF
Quality Mix High Flow Air-Oxygen-Blender
• Total flow maximum: 110 LPM
• Configurable with up to 3 flowmeters
• An oxygen monitor can be added to the Blender to
check the precise FiO2 concentration
• With an extra pressure module, different input
pressures of AIR and O2 can be compensated
• Audible warning in case of gas failure
• Robust and intelligent design due to recessed
adjusting knob
• The O2 mixer is MRI compatible
Order Number: QM-HF
Quality Mix Air-Oxygen blender with Quality MonO2 Oxygen-Monitor (Example of use)
Bio-Med „NEO2 BLEND“ Air-Oxygen-Blender
• Total flow maximum: 30 LPM
• With switchable bleed-function (on/off)
• Pre-configured with 2 flowmeters
(0-15 LPM and 0-1 LPM or 0-3,5 LPM)
• Audible warning in case of gas failure
• Robust design
• Has a pivoting system - quick activation and
deactivation of the flow by simply tilting the
flowmeter
Bestellnummer / Order Number: BM-N2
Maxtec MaxBlend2 Low Flow
Air-Oxygen-Blender
• Total flow maximum: 30 LPM
• Available with 3 LPM, 15 LPM or 30 LPM
dual-scale flowmeter with backlight
• Optional upgrade with a second flowmeter
possible
• Audible warning in case of gas failure
• With switchable bleed-function (on/off )
• Integrated O2 monitoring with adjustable alarm
limits
• Large, backlit LCD with low-light sensor
• DC power port
Order Number: MB2-LF
Maxtec MaxBlend2 High Flow
Aix-Oxygen-Blender
• Total flow maximum: 100 LPM
• Available with 70 LPM dual-scale flowmeter
with backlight
• Optional upgrade with a second flowmeter
possible
• Audible warning in case of gas failure
• Integrated O2 monitoring with adjustable
alarm limits
• Large, backlit LCD with low-light sensor
• DC power port
Order Number: MB2-HF